| Item details | ||||||||
| HUBER+SUHNER Type | 3410.41.0030 | |||||||
| RF Protector Description | High-power/low-IM GDT hybrid technology with bias-T | |||||||
| Highlights |
| |||||||
| External Remarks | - Supports AISG signal and DC feed between TNC- and unprotected side (7/16 female) - Resistance DC injection port: <10 mOhm - Mounting screw set for M8 and bulkhead mounting material included - Recommended TNC DC-assembly connector: 11_TNC-50-2-27 84101205 with shrink adhs 90056301 | |||||||
| Item number | 84115182 (Rev. A) | |||||||
| Gas Tube | included | |||||||
| Data sheet | ||||||||
| 2002/95/EC [RoHS] | Telecom compliant | |||||||
| Assembly configuration | Jump to [Top] | |||||||
| Main Path Connector | unprotected side (Port1) | 7/16 «jack (female)» | ||||||
| protected side (Port2) | 7/16 «plug (male)» | |||||||
| Connector Port3 | DC Injection | TNC «jack (female)» | ||||||
| Side of Bulkhead | unprotected side | |||||||
| Bulkhead mounting | Mounting Hole | MH110 | ||||||
| Screw mounting | Thread | M8 | ||||||
| Right Angle | ||||||||
| Electrical data | Jump to [Top] | |||||||
| Impedance | 50 | Ω | ||||||
| Residual Pulse Energy | test pulse 4 kV 1.2/50µs / 2 kA 8/20µs | 20 | typ. µJ | |||||
| Port3 Res. Pulse Energy | 300 | µJ | ||||||
| Current Handling 8/20 | test pulse 8/20µs | 30 single / 20 multiple | kA | |||||
| Port 3 Coupling | 30 | dB | ||||||
| DC Current | ≤3.5 | A | ||||||
| DC Voltage | ≤48 | V | ||||||
| DC Resistance | 10 | mOhm | ||||||
| Range 1 | Range 2 | Frame | ||||||
| Frequency range | 690 to 960 MHz | 1700 to 2200 MHz | 690 to 2200 | MHz | ||||
| Return loss | ≥ 24 dB | ≥ 24 dB | ≥ 22 | dB | ||||
| Insertion loss | ≤ 0.1 dB | ≤ 0.1 dB | ≤ 0.1 | dB | ||||
| CW power | ≤ 500 W | ≤ 500 W | ≤ 500 | W | ||||
| PIM 3rd order | -155 max. | dBc | ||||||
| Environmental and general data | Jump to [Top] | |||||||
| Operating Temp min. | -40 | °C | ||||||
| Operating Temp max. | 85 | °C | ||||||
| IP Rating | according to IEC 60529, data refer to the coupled state | IP 67 | ||||||
| Weight | 592 | g | ||||||
| Number of Matings | 500 | |||||||
| Material data | Jump to [Top] | |||||||
| 2002/95/EC [RoHS] | Telecom compliant | |||||||
| Piece part | Base material | Plating | ||||||
| Body | Brass | |||||||
| Port1 Centre Contact Material | Bronze | Silver | ||||||
| Port2 Center Contact Material | Brass | Silver | ||||||
| Tests | Jump to [Top] | |||||||
| Following tests have been passed successfully. For any details please contact your nearest HUBER+SUHNER representative. | ||||||||
| Test description | Specification / Paragraph / Method | |||||||
| Temperature Shock | MIL-STD-202, Method 107, Cond. B | |||||||
| Vibration | MIL-STD-202, Method 204, Cond. D | |||||||
| Moisture Resistance | MIL-STD-202, Method 106 | |||||||