Applications
| each-to-each | against ref. | ||||||||||||||||||
| IL1) |
IEC 61755-2-2 97% 0.15 dB mean 0.06 dB |
max. 0.15 dB |
|||||||||||||||||
| RL |
IEC 61300-3-6 >45 dB >50 dB >85 dB |
PC UPC APC |
|||||||||||||||||
1) at 1310 nm
Compatibility
Please note
0.1dB assemblies have max. losses lower than the accuracy of todays field measurements: Measurement equipment (power meter /OTDR) and measurement set-up, reference cables and adapters, environmental conditions and dirt easily cause measurement uncertainities of >0.2dB. Reliable and reproducible measurements below 0.1dB are possible only under laboratory conditions.